5012A-E46TAG ElectropaK

Electric Power Generation 5012A-E46TAG

Request Consultation Find your Distributor

Key Specs

Gross Mechanical Output
921-1638 kW
921-1638 kW
Typical Electrical Output
1020-1875 kVA (816-1500 kWe)
1020-1875 kVA (816-1500 kWe)
Emissions
Fuel Optimised
Fuel Optimised

Overview

The Perkins® 5012A-E46TAG has been designed to offer reliable power for all electric power applications, including standby, prime, critical and data centres.

Engineered and built specifically for the power generation market, the Perkins® 5000 Series is a power-packed engine range built to be dependable, versatile and offer low daily operating costs.

Product Specifications for 5012A-E46TAG

Gross Mechanical Output 921-1638 kW 921-1638 kW
Typical Electrical Output 1020-1875 kVA (816-1500 kWe) 1020-1875 kVA (816-1500 kWe)
Rated Speed 1500 rpm 1500 rpm
Emissions Fuel Optimised Fuel Optimised
Prime 1275-1710 kVA (1020-1368 kWe) 1275-1710 kVA (1020-1368 kWe)
Standby 1400-1875 KVA (1120-1500 kWe) 1400-1875 KVA (1120-1500 kWe)
Baseload 1020-1368 kVA (816-1094 kWe) 1020-1368 kVA (816-1094 kWe)
Number of Cylinders 12 Vee 12 Vee
Bore 6.3 in 160 mm
Stroke 7.5 in 190 mm
Displacement 2797.3 in³ 45.84 l
Compression Ratio 13.8:1 13.8:1
Aspiration Turbocharged and air-to-air chargecooled Turbocharged and air-to-air chargecooled
Combustion System Direct injection Direct injection
Rotation from Flywheel End Anti-clockwise Anti-clockwise
Cooling System Watercooled Watercooled
Aftertreatment N/A N/A
Typical Alternator Efficiency 95% 95%
Switchable No No
Length 154.1 in 3913 mm
Width 86.6 in 2200 mm
Height 102.9 in 2614 mm
Dry Weight 12919 lb 5860 kg
Note 1 *Final dimensions dependent on selected options *Final dimensions dependent on selected options
Prime Power Unlimited hours usage with an average load factor of 80 percent of the published prime power over each 24 hour period. A 10 percent overload is available for one hour in every 12 hours operation. Unlimited hours usage with an average load factor of 80 percent of the published prime power over each 24 hour period. A 10 percent overload is available for one hour in every 12 hours operation.
Standby Power Limited to 500 hours usage with an average load factor of 80 percent of the published standby power rating over each 24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted. Limited to 500 hours usage with an average load factor of 80 percent of the published standby power rating over each 24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted.
Baseload Unlimited hours usage with an average load factor of 100 percent of the published continuous operating power. No overload is permitted on continuous operating power. Unlimited hours usage with an average load factor of 100 percent of the published continuous operating power. No overload is permitted on continuous operating power.

5012A-E46TAG Standard Equipment

Electro unit or ElectropaK

  • Both

Radiator fitted

  • Loose

Fuel filter

  • Engine mounted

Water separator

  • N/A

Fuel priming pump (manual/electric)

  • Electric

Fuel cooler

  • Not required for most installations

Air filter

  • Engine mounted

Engine ECM

  • Engine mounted

Wiring harness

  • To ECM
  • All connectors to single customer interface

Temperature and oil pressure for automatic stop/alarm

  • Configurable

See how 5012A-E46TAG compares against frequently compared products.