Total Power Range
Gross Mechanical Output | 533-788 kW 533-788 kW |
Typical Electrical Output | 600-900 kVA (480-720 kWe) 600-900 kVA (480-720 kWe) |
Rated Speed | 1500 rpm 1500 rpm |
Key Specs
The Perkins® 5006AC-E23TAG has been designed to offer reliable power for all electric power applications, including standby, prime, critical and data centres.
Engineered and built specifically for the power generation market, the Perkins® 5000 Series is a power-packed engine range built to be dependable, versatile and offer lower emissions to meet regulatory standards.
Gross Mechanical Output | 533-788 kW 533-788 kW |
Typical Electrical Output | 600-900 kVA (480-720 kWe) 600-900 kVA (480-720 kWe) |
Rated Speed | 1500 rpm 1500 rpm |
Prime | 750-800 kVA (600-640 kWe) 750-800 kVA (600-640 kWe) |
Standby | 825-900 KVA (660-720 kWe) 825-900 KVA (660-720 kWe) |
Baseload | 600-640 kVA (480-512 kWe) 600-640 kVA (480-512 kWe) |
Emissions | Equivalent to U.S. EPA Tier 2 Equivalent to U.S. EPA Tier 2 |
Number of Cylinders | 6 6 |
Bore | 6.3 in 160 mm |
Stroke | 7.5 in 190 mm |
Displacement | 1398.73 in³ 22.921 l |
Compression Ratio | 13.8:1 13.8:1 |
Aspiration | Turbocharged and air-to-air chargecooled Turbocharged and air-to-air chargecooled |
Combustion System | Direct injection Direct injection |
Rotation from Flywheel End | Anti-clockwise Anti-clockwise |
Cooling System | Watercooled Watercooled |
Aftertreatment | N/A N/A |
Typical Alternator Efficiency | 94% 94% |
Switchable | No No |
Length | 107.4 in 2730 mm |
Width | 66.5 in 1690 mm |
Height | 83.7 in 2126 mm |
Dry Weight | 6195 lb 2810 kg |
Length | 89.6 in 2276 mm |
Width | 56.9 in 1446 mm |
Height | 68.7 in 1745 mm |
Dry Weight | 5303 lb 2405 kg |
Note 1 | *Final dimensions dependent on selected options *Final dimensions dependent on selected options |
Prime Power | Unlimited hours usage with an average load factor of 80 percent of the published prime power over each 24 hour period. A 10 percent overload is available for one hour in every 12 hours operation. Unlimited hours usage with an average load factor of 80 percent of the published prime power over each 24 hour period. A 10 percent overload is available for one hour in every 12 hours operation. |
Standby Power | Limited to 500 hours usage with an average load factor of 80 percent of the published standby power rating over each 24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted. Limited to 500 hours usage with an average load factor of 80 percent of the published standby power rating over each 24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted. |
Baseload | Unlimited hours usage with an average load factor of 100 percent of the published continuous operating power. No overload is permitted on continuous operating power. Unlimited hours usage with an average load factor of 100 percent of the published continuous operating power. No overload is permitted on continuous operating power. |