Total Power Range
Gross Mechanical Output | 127-160 kWm 127-160 kWm |
Typical Electrical Output | 135-169 kVA (108-135 kWe) 135-169 kVA (108-135 kWe) |
Rated Speed | 1500/1800 rpm 1500/1800 rpm |
Key Specs
The 6 cylinder, 7 litre Perkins 1106 range of ElectropaK engines gives you all the power you need for electric power generation. The engines in the range share a common platform with the option of mechanical and common rail fuel systems enabling use of the same platform over different emissions territories. Reliable, dependable and with a low cost of ownership, the engines can cope with variations in fuel quality that occur in different parts of the world.
Gross Mechanical Output | 127-160 kWm 127-160 kWm |
Typical Electrical Output | 135-169 kVA (108-135 kWe) 135-169 kVA (108-135 kWe) |
Rated Speed | 1500/1800 rpm 1500/1800 rpm |
Emissions | Fuel Optimised Fuel Optimised |
Prime | 135 kVA 135 kVA |
Standby | 150 kVA 150 kVA |
Prime | 121.5 kWe 121.5 kWe |
Standby | 135 kWe 135 kWe |
Number of Cylinders | 6 vertical inline 6 vertical inline |
Bore | 4.13 in 105 mm |
Stroke | 5.3 in 135 mm |
Displacement | 428 in³ 7 l |
Compression Ratio | 18.2:1 18.2:1 |
Aspiration | Turbocharged Turbocharged |
Combustion System | Direct injection Direct injection |
Rotation from Flywheel End | Anti-clockwise Anti-clockwise |
Cooling System | Liquid Liquid |
Aftertreatment | - - |
Typical Alternator Efficiency | 91% 91% |
Switchable | No No |
Length | 65 in 1648 mm |
Width | 30 in 760 mm |
Height | 43 in 1092 mm |
Dry Weight | 1629 lb 739 kg |
Note 1 | *Final dimensions dependent on selected options *Final dimensions dependent on selected options |
Prime Power | Unlimited hours usage, with an average load factor of 80 percent over each 24 hour period. A 10 percent overload is available for 1 hour in every12 hours operation. Unlimited hours usage, with an average load factor of 80 percent over each 24 hour period. A 10 percent overload is available for 1 hour in every12 hours operation. |
Standby Power | Limited to 500 hours annual usage, with an average load factor of 80 percent of the published Standby power rating over each 24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted on Standby power. Limited to 500 hours annual usage, with an average load factor of 80 percent of the published Standby power rating over each 24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted on Standby power. |