Overview
Perkins® 5016C-E61TRG delivers reliable power for emergency standby and critical applications, including data centres and hospitals.
Key Specs
Perkins® 5016C-E61TRG delivers reliable power for emergency standby and critical applications, including data centres and hospitals.
Displaying 1-6 of 4
| Gross Mechanical Output | 1774-2216 kW 1774-2216 kW |
| Typical Electrical Output | 1969-2500 kVA (1575-2000 kWe) 1969-2500 kVA (1575-2000 kWe) |
| Rated Speed | 1800 rpm 1800 rpm |
| Emissions | U.S. EPA Stationary Emergency Engine emits equivalent to Tier 2 U.S. EPA Stationary Emergency Engine emits equivalent to Tier 2 |
| Standby | 1969-2500 kVA (1575-2000 kWe) 1969-2500 kVA (1575-2000 kWe) |
| Number of Cylinders | 16 16 |
| Displacement | 3728.6 in³ 61.1 l |
| Aspiration | Turbocharged and air-to-water chargecooled Turbocharged and air-to-water chargecooled |
| Bore | 6.3 in 160 mm |
| Stroke | 7.5 in 190 mm |
| Combustion System | Direct injection Direct injection |
| Compression Ratio | 13.8:1 13.8:1 |
| Aftertreatment | None None |
| Total Lubricating Oil Capacity | 56.3 gal (US) 213 l |
| Total Coolant Capacity | 130.5 gal (US) 494 l |
| Rotation from Flywheel End | Anti-clockwise Anti-clockwise |
| Cooling System | Liquid Liquid |
| Typical Alternator Efficiency | 95% 95% |
| Switchable | No No |
| Length | 184.5 in 4687 mm |
| Width | 86 in 2184 mm |
| Height | 147 in 3735 mm |
| Dry Weight | 18428 lb 8359 kg |
| Wet Weight | 20007 lb 9075 kg |
| Note 1 | *Generator powers are typical and based on typical alternator efficiencies and a power factor (cos θ) or 0.8 *Generator powers are typical and based on typical alternator efficiencies and a power factor (cos θ) or 0.8 |
| Note 2 | *Final dimensions dependent on selected options *Final dimensions dependent on selected options |
| Emergency standby power (ESP) | Limited to 200 hours usage per year with an average load factor of 80 percent of the published ESP rating over each 24 hour period. Limited to 200 hours usage per year with an average load factor of 80 percent of the published ESP rating over each 24 hour period. |
| Data centre power (DCP) | Power available for variable or continuous electrical loads in a data centre application. Up to 100 percent load factor of the published DCP power is permitted for unlimited time. An overload of 10 percent is permitted for one hour in every 12 hours of operation*. DCP power definition relies on ISO8528-1 2018 standard to be followed by generator set manufacturer, and will support Tier I to Tier IV classifications of data centres as per UPTIME institute guidelines. *No overload permitted for 5016TRG3X rating. Power available for variable or continuous electrical loads in a data centre application. Up to 100 percent load factor of the published DCP power is permitted for unlimited time. An overload of 10 percent is permitted for one hour in every 12 hours of operation*. DCP power definition relies on ISO8528-1 2018 standard to be followed by generator set manufacturer, and will support Tier I to Tier IV classifications of data centres as per UPTIME institute guidelines. *No overload permitted for 5016TRG3X rating. |