Total Power Range
Gross Mechanical Output | 1269-2183 kWm 1269-2183 kWm |
Typical Electrical Output | 1400-2500 kVA (1120-2000 kWe) 1400-2500 kVA (1120-2000 kWe) |
Rated Speed | 1500 rpm 1500 rpm |
Key Specs
Our 4016 range gives you the versatility and heavy duty performance you need in today's power generation market. The Perkins 4016 engines feature 16 cylinders and a massive 61 litre displacement in both ElectropaK and Electro Unit variants. The 4016 range offers 1400-2500 kVA generator output. Our 4016 range engines have exceptional power-to-weight ratio and compact design, making them easy to transport and install.
Gross Mechanical Output | 1269-2183 kWm 1269-2183 kWm |
Typical Electrical Output | 1400-2500 kVA (1120-2000 kWe) 1400-2500 kVA (1120-2000 kWe) |
Rated Speed | 1500 rpm 1500 rpm |
Emissions | Fuel Optimised Fuel Optimised |
Prime | 1850-2250 kVA 1850-2250 kVA |
Standby | 2000-2500 kVA 2000-2500 kVA |
Baseload | 1400-1800 kVA 1400-1800 kVA |
Number of Cylinders | 16 Vee 16 Vee |
Bore | 6.3 in 160 mm |
Stroke | 7.5 in 190 mm |
Displacement | 3730 in³ 61.1 l |
Compression Ratio | 13.0:1 13.0:1 |
Aspiration | Quad turbocharged and air-to-water charge cooled Quad turbocharged and air-to-water charge cooled |
Combustion System | Direct injection Direct injection |
Rotation from Flywheel End | Anti-clockwise Anti-clockwise |
Cooling System | Liquid Liquid |
Aftertreatment | - - |
Typical Alternator Efficiency | 95-96% 95-96% |
Switchable | No No |
Length | 179 in 4542 mm |
Width | 86 in 2185 mm |
Height | 125 in 3175 mm |
Dry Weight | 17162 lb 7783 kg |
Note 1 | *Final dimensions dependent on selected options *Final dimensions dependent on selected options |
Prime Power | Variable load. Unlimited hours usage with an average load factor of 80% of the published prime power over each 24 hour period. A 10% overload is available for 1 hour in every 12 hour operation. Variable load. Unlimited hours usage with an average load factor of 80% of the published prime power over each 24 hour period. A 10% overload is available for 1 hour in every 12 hour operation. |
Standby Power | Limited to 500 hours annual usage with an average load factor of 80% of the published standby power rating over each 24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted on standby power. Limited to 500 hours annual usage with an average load factor of 80% of the published standby power rating over each 24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted on standby power. |
Baseload | Unlimited hours usage with an average load factor of 100% of the published baseload power. No overload is permitted on baseload power. Unlimited hours usage with an average load factor of 100% of the published baseload power. No overload is permitted on baseload power. |