Note that by entering data in this application for purposes of obtaining
driving directions, you are providing such data directly to Google LLC and/or its affiliates. By
clicking "I Agree" or by using the Google Maps functionality to obtain driving directions, you
acknowledge and agree that use of Google Maps is subject to the then-current Google Maps/Google Earth
Additional Terms of Service at
https://developers.google.com/maps/terms-20180207#section_9_3
and Google Privacy Policy at
https://policies.google.com/privacy
1400-2500 kVA (1120-2000 kWe)1400-2500 kVA (1120-2000 kWe)
1463-2263 kVA (1170-1811 kWe)1463-2263 kVA (1170-1811 kWe)
600-900 kVA (480-720 kWe)600-900 kVA (480-720 kWe)
Rated Speed
1500 rpm1500 rpm
1500 rpm1500 rpm
1500 rpm1500 rpm
Emission Standards
Emissions
Fuel OptimisedFuel Optimised
Fuel OptimisedFuel Optimised
Equivalent to U.S. EPA Tier 2Equivalent to U.S. EPA Tier 2
50 Hz Typical Electrical Output
Prime
1850-2250 kVA1850-2250 kVA
1844-2058 kVA1844-2058 kVA
750-800 kVA (600-640 kWe)750-800 kVA (600-640 kWe)
Standby
2000-2500 kVA2000-2500 kVA
2028-2263 kVA2028-2263 kVA
825-900 KVA (660-720 kWe)825-900 KVA (660-720 kWe)
Baseload
1400-1800 kVA1400-1800 kVA
1463-1634 kVA1463-1634 kVA
600-640 kVA (480-512 kWe)600-640 kVA (480-512 kWe)
General
Number of Cylinders
16 Vee16 Vee
16 Vee16 Vee
66
Bore
6.3 in160 mm
6.3 in160 mm
6.3 in160 mm
Stroke
7.5 in190 mm
7.5 in190 mm
7.5 in190 mm
Displacement
3730 in³61.1 l
16.2 in³61.1 l
1398.73 in³22.921 l
Compression Ratio
13.0:113.0:1
13.6:113.6:1
13.8:113.8:1
Aspiration
Quad turbocharged and air-to-water charge cooledQuad turbocharged and air-to-water charge cooled
Turbocharged and air-to-air charge cooledTurbocharged and air-to-air charge cooled
Turbocharged and air-to-air chargecooledTurbocharged and air-to-air chargecooled
Combustion System
Direct injectionDirect injection
Direct injectionDirect injection
Direct injectionDirect injection
Rotation from Flywheel End
Anti-clockwiseAnti-clockwise
Anti-clockwiseAnti-clockwise
Anti-clockwiseAnti-clockwise
Cooling System
LiquidLiquid
LiquidLiquid
WatercooledWatercooled
Aftertreatment
--
--
N/AN/A
Typical Alternator Efficiency
95-96%95-96%
96%96%
94%94%
Switchable
NoNo
NoNo
NoNo
ElectropaK Dimensions
Length
179 in4542 mm
-
107.4 in2730 mm
Width
86 in2185 mm
-
66.5 in1690 mm
Height
125 in3175 mm
-
83.7 in2126 mm
Dry Weight
17162 lb7783 kg
-
6195 lb2810 kg
Engine Dimensions*
Length
-
130 in3302 mm
89.6 in2276 mm
Width
-
67.8 in1723 mm
56.9 in1446 mm
Height
-
83.8 in2128 mm
68.7 in1745 mm
Dry Weight
-
12282 lb5570 kg
5303 lb2405 kg
Disclaimer
Note 1
*Final dimensions dependent on selected options*Final dimensions dependent on selected options
*Final dimensions dependent on selected options*Final dimensions dependent on selected options
*Final dimensions dependent on selected options*Final dimensions dependent on selected options
Definitions
Prime Power
Variable load. Unlimited hours usage with an average load factor of 80% of the published prime power over each 24 hour period. A 10% overload is available for 1 hour in every 12 hour operation.Variable load. Unlimited hours usage with an average load factor of 80% of the published prime power over each 24 hour period. A 10% overload is available for 1 hour in every 12 hour operation.
Variable load. Unlimited hours usage with an average load factor of 80% of the published prime power over each 24 hour period. A 10% overload is available for 1 hour in every 12 hour operation.Variable load. Unlimited hours usage with an average load factor of 80% of the published prime power over each 24 hour period. A 10% overload is available for 1 hour in every 12 hour operation.
Unlimited hours usage with an average load factor of 80 percent of the published prime power over each 24 hour period.
A 10 percent overload is available for one hour in every 12 hours operation.Unlimited hours usage with an average load factor of 80 percent of the published prime power over each 24 hour period.
A 10 percent overload is available for one hour in every 12 hours operation.
Standby Power
Limited to 500 hours annual usage with an average load factor of 80% of the published standby power rating over each 24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted on standby power.Limited to 500 hours annual usage with an average load factor of 80% of the published standby power rating over each 24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted on standby power.
Limited to 500 hours annual usage with an average load factor of 80% of the published standby power rating over each 24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted on standby power.Limited to 500 hours annual usage with an average load factor of 80% of the published standby power rating over each 24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted on standby power.
Limited to 500 hours usage with an average load factor of 80 percent of the published standby power rating over each
24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted.Limited to 500 hours usage with an average load factor of 80 percent of the published standby power rating over each
24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted.
Baseload
Unlimited hours usage with an average load factor of 100% of the published baseload power. No overload is permitted on baseload power.Unlimited hours usage with an average load factor of 100% of the published baseload power. No overload is permitted on baseload power.
Unlimited hours usage with an average load factor of 100% of the published baseload power. No overload is permitted on baseload power.Unlimited hours usage with an average load factor of 100% of the published baseload power. No overload is permitted on baseload power.
Unlimited hours usage with an average load factor of 100 percent of the published continuous
operating power. No overload is permitted on continuous operating power.Unlimited hours usage with an average load factor of 100 percent of the published continuous
operating power. No overload is permitted on continuous operating power.
Compare models by clicking "Add a Model" above to load specification data.
Please note: You are not currently able to compare with competitors. Please check again at a later date.
Dealer Price
Taxes, shipping & handling, surcharges, assembly charges, destination, freight and/or delivery charges are not included.This is not an offer for sale. Displayed pricing identified as Dealer Price is for informational purposes only. The displayed pricing identified as “dealer price” is the lowest price shown for the machine configurations shown on the page accessed through the “Build Your Own” button. The price includes the attachments (if any) and features shown as being included with the lowest priced machine configuration on the page accessed through the “Build Your Own” button and does not include any other attachments or protection plans.The actual prices and terms and conditions of sale for all products are to be solely determined by the selling authorized Cat dealer and agreed to with the purchaser at the time of a final sale.
MSRP
This is not an offer for sale. The MSRP price displayed is for informational purposes. Please note that the MSRP may vary by authorized Cat dealer for the same product. The actual price and terms and conditions of sale for all products are to be solely determined by the selling authorized Cat dealer at the time of sale. Taxes, shipping & handling charges, surcharges, assembly charges, destination, freight and/or delivery charges are not included in the MSRP shown. The displayed pricing identified as the “MSRP” price includes features shown for the lowest priced machine configuration on the page accessed through the “Shop Now” button and does not include any attachments or protection plans.
MSRP
Price listed is Manufacturer's Suggested Retail Price, this price does not include shipping and handling, expedite charges, taxes, dealer installation costs or other dealer charges. Dealers set actual prices, including invoicing currency. The MSRP displayed is for the region selected.
Price listed is Manufacturer's Suggested Retail Price, this price does not include shipping and handling, expedite charges, taxes, dealer installation costs or other dealer charges. Dealers set actual prices, including invoicing currency. The MSRP displayed is for the region selected.