4006-23TAG Electric Power Diesel Engine

Electric Power Generation 4006-23TAG

Request Consultation Find your Distributor

Key Specs

Gross Mechanical Output
531-886 kWm
531-886 kWm
Typical Electrical Output
595-1000 kVA (476-800 kWe)
595-1000 kVA (476-800 kWe)
Emissions
Fuel Optimised
Fuel Optimised

Overview

The 6 cylinder Perkins 4006 range gives you the versatility you need in today's power generation market. The range's diesel ElectropaK engines/Electro Units deliver 750-900 kVA and are supplied with or without radiator and air cleaner. This engine has proven reliability in prime and standby installations in all of the key sectors, such as manufacturing facilities, hospitals, and data centres. The 4006 engines have exceptional power-to-weight ratios and compact designs, making them simple to transport and install.

Product Specifications for 4006-23TAG

Gross Mechanical Output 531-886 kWm 531-886 kWm
Typical Electrical Output 595-1000 kVA (476-800 kWe) 595-1000 kVA (476-800 kWe)
Rated Speed 1500/1800 rpm 1500/1800 rpm
Emissions Fuel Optimised Fuel Optimised
Prime 746-802 KVA 746-802 KVA
Standby 820-898 KVA 820-898 KVA
Baseload 595-637 kVA 595-637 kVA
Prime 600-722 kWe 600-722 kWe
Standby 660-800 kWe 660-800 kWe
Baseload 480-572 kWe 480-572 kWe
Number of Cylinders 6 inline 6 inline
Bore 6.3 in 160 mm
Stroke 7.5 in 190 mm
Displacement 1399 in³ 23 l
Compression Ratio 13.6:1 13.6:1
Aspiration Turbocharged and air-to-air charge cooled Turbocharged and air-to-air charge cooled
Combustion System Direct injection Direct injection
Rotation from Flywheel End Anti-clockwise Anti-clockwise
Cooling System Liquid Liquid
Aftertreatment - -
Typical Alternator Efficiency 90-95% 90-95%
Switchable Yes Yes
Length 115.2 in 2927 mm
Width 66.5 in 1690 mm
Height 83.7 in 2125 mm
Dry Weight 5565 lb 2524 kg
Note 1 *Final dimensions dependent on selected options *Final dimensions dependent on selected options
Prime Power Unlimited hours usage with an average load factor of 80% of the published prime power over each 24 hours period. A 10% overload is available for Unlimited hours usage with an average load factor of 80% of the published prime power over each 24 hours period. A 10% overload is available for
Standby Power Limited to 500 hours annual usage with an average load factor of 80% of the published standby power rating over each 24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted on standby power. Limited to 500 hours annual usage with an average load factor of 80% of the published standby power rating over each 24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted on standby power.
Baseload Unlimited hours usage with an average load factor of 100% of the published baseload power. No overload is permitted on baseload power. Unlimited hours usage with an average load factor of 100% of the published baseload power. No overload is permitted on baseload power.

4006-23TAG Standard Equipment

Air inlet system

  • Mounted air filter and turbocharger

Cooling system

  • Radiator supplied loose incorporating air-to-air charge cooler
  • System designed for ambients up to 50ºC (122ºF)
  • Twin thermostats, water pump

Electrical equipment

  • 24V starter motor, 24V alternator with integral voltage regulator and DC output
  • High coolant temperature protection switch
  • Low oil pressure protection switch
  • Turbine inlet temperature protection

Flywheel and housing

  • SAE ‘0' flywheel housing
  • SAE J620 size 18 flywheel

Fuel system

  • Digital governing to ISO 8528-5 Class G2 with isochronous capability
  • Direct fuel injection system with fuel lift pump
  • Full flow spin-on filters

Lubrication system

  • Full flow spin-on oil filters
  • Wet full aluminium sump with filler and dipstick

Optional equipment

  • 4 meter wiring harness
  • Exhaust counter flanges
  • Immersion heater
  • Secondary electric start
  • Single exhaust outlet pipe
  • Temperate radiator kit

See how 4006-23TAG compares against frequently compared products.