1020-1875 kVA (816-1500 kWe)1020-1875 kVA (816-1500 kWe)
1020-1875 kVA (816-1500 kWe)1020-1875 kVA (816-1500 kWe)
1408-1876 kVA (1127-1501 kWe)1408-1876 kVA (1127-1501 kWe)
Rated Speed
1500 rpm1500 rpm
1500 rpm1500 rpm
1800 rpm1800 rpm
50 Hz Typical Electrical Output
Prime
1275-1710 kVA (1020-1368 kWe)1275-1710 kVA (1020-1368 kWe)
1275-1710 kVA (1020-1368 kWe)1275-1710 kVA (1020-1368 kWe)
-
Standby
1400-1875 KVA (1120-1500 kWe)1400-1875 KVA (1120-1500 kWe)
1400-1875 KVA (1120-1500 kWe)1400-1875 KVA (1120-1500 kWe)
-
Baseload
1020-1368 kVA (816-1094 kWe)1020-1368 kVA (816-1094 kWe)
1020-1368 kVA (816-1094 kWe)1020-1368 kVA (816-1094 kWe)
-
Emission Standards
Emissions
Fuel OptimisedFuel Optimised
Equivalent to U.S. EPA Tier 2Equivalent to U.S. EPA Tier 2
U.S. EPA Stationary Emergency Engine emits equivalent to Tier 2U.S. EPA Stationary Emergency Engine emits equivalent to Tier 2
General
Number of Cylinders
12 Vee12 Vee
12 Vee12 Vee
12 Vee12 Vee
Bore
6.3 in160 mm
6.3 in160 mm
6.3 in160 mm
Stroke
7.5 in190 mm
7.5 in190 mm
7.5 in190 mm
Displacement
2797.3 in³45.84 l
2797.3 in³45.84 l
2797.3 in³45.84 l
Compression Ratio
13.8:113.8:1
13.8:113.8:1
13.8:113.8:1
Aspiration
Turbocharged and air-to-air chargecooledTurbocharged and air-to-air chargecooled
Turbocharged and air-to-air chargecooledTurbocharged and air-to-air chargecooled
Turbocharged and air-to-air chargecooledTurbocharged and air-to-air chargecooled
Combustion System
Direct injectionDirect injection
Direct injectionDirect injection
Direct injectionDirect injection
Rotation from Flywheel End
Anti-clockwiseAnti-clockwise
Anti-clockwiseAnti-clockwise
Anti-clockwiseAnti-clockwise
Cooling System
WatercooledWatercooled
WatercooledWatercooled
LiquidLiquid
Total Lubricating Oil Capacity
-
-
41.61 gal (US)157.5 l
Total Coolant Capacity
-
-
58.38 gal (US)221 l
Aftertreatment
N/AN/A
N/AN/A
NoneNone
Typical Alternator Efficiency
95%95%
95%95%
95%95%
Switchable
NoNo
NoNo
NoNo
60 Hz Typical Electrical Output
Prime
-
-
1408-1688 kVA (1127-1351 kWe)1408-1688 kVA (1127-1351 kWe)
Standby
-
-
1563-1876 kVA (1250-1501 kWe)1563-1876 kVA (1250-1501 kWe)
ElectropaK Dimensions
Length
154.1 in3913 mm
154.1 in3913 mm
163.1 in4143 mm
Width
86.6 in2200 mm
86.6 in2200 mm
86.6 in2200 mm
Height
102.9 in2614 mm
102.9 in2614 mm
89.5 in2273 mm
Dry Weight
12919 lb5860 kg
12919 lb5860 kg
12919 lb5860 kg
Wet Weight
-
-
13735 lb6230 kg
Disclaimer
Note 1
*Final dimensions dependent on selected options*Final dimensions dependent on selected options
*Final dimensions dependent on selected options*Final dimensions dependent on selected options
*Generator powers are typical and based on typical alternator efficiencies and a power factor (cos θ) or 0.8*Generator powers are typical and based on typical alternator efficiencies and a power factor (cos θ) or 0.8
Note 2
-
-
*Final dimensions dependent on selected options*Final dimensions dependent on selected options
Definitions
Prime Power
Unlimited hours usage with an average load factor of 80 percent of the published prime power over each 24 hour period.
A 10 percent overload is available for one hour in every 12 hours operation.Unlimited hours usage with an average load factor of 80 percent of the published prime power over each 24 hour period.
A 10 percent overload is available for one hour in every 12 hours operation.
Unlimited hours usage with an average load factor of 80 percent of the published prime power over each 24 hour period.
A 10 percent overload is available for one hour in every 12 hours operation.Unlimited hours usage with an average load factor of 80 percent of the published prime power over each 24 hour period.
A 10 percent overload is available for one hour in every 12 hours operation.
-
Standby Power
Limited to 500 hours usage with an average load factor of 80 percent of the published standby power rating over each
24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted.Limited to 500 hours usage with an average load factor of 80 percent of the published standby power rating over each
24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted.
Limited to 500 hours usage with an average load factor of 80 percent of the published standby power rating over each
24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted.Limited to 500 hours usage with an average load factor of 80 percent of the published standby power rating over each
24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted.
-
Emergency standby power (ESP)
-
-
Limited to 200 hours usage per year with an average load factor of 80 percent of the published ESP rating over each 24 hour period.Limited to 200 hours usage per year with an average load factor of 80 percent of the published ESP rating over each 24 hour period.
Baseload
Unlimited hours usage with an average load factor of 100 percent of the published continuous
operating power. No overload is permitted on continuous operating power.Unlimited hours usage with an average load factor of 100 percent of the published continuous
operating power. No overload is permitted on continuous operating power.
Unlimited hours usage with an average load factor of 100 percent of the published continuous
operating power. No overload is permitted on continuous operating power.Unlimited hours usage with an average load factor of 100 percent of the published continuous
operating power. No overload is permitted on continuous operating power.
-
Data centre power (DCP)
-
-
Power available for variable or continuous electrical loads in a data centre application. Up to 100 percent load factor of the published DCP power is permitted for unlimited time. An overload of 10 percent is permitted for one hour in every 12 hours of operation. No overload is permitted. DCP power definition relies on ISO8528-1 2018 standard to be followed by generator set manufacturer, and will support Tier I to Tier IV classifications of data centres as per UPTIME institute guidelines.Power available for variable or continuous electrical loads in a data centre application. Up to 100 percent load factor of the published DCP power is permitted for unlimited time. An overload of 10 percent is permitted for one hour in every 12 hours of operation. No overload is permitted. DCP power definition relies on ISO8528-1 2018 standard to be followed by generator set manufacturer, and will support Tier I to Tier IV classifications of data centres as per UPTIME institute guidelines.
Compare models by clicking "Add a Model" above to load specification data.
The ability to compare with competitors is currently not available for this model. Please check back at a later date.
Dealer Price
Taxes, shipping & handling, surcharges, assembly charges, destination, freight and/or delivery charges are not included.This is not an offer for sale. Displayed pricing identified as Dealer Price is for informational purposes only. The displayed pricing identified as “dealer price” is the lowest price shown for the machine configurations shown on the page accessed through the “Build Your Own” button. The price includes the attachments (if any) and features shown as being included with the lowest priced machine configuration on the page accessed through the “Build Your Own” button and does not include any other attachments or protection plans.The actual prices and terms and conditions of sale for all products are to be solely determined by the selling authorized Cat dealer and agreed to with the purchaser at the time of a final sale.
MSRP
The displayed pricing identified as the "MSRP" price is the Manufacturer’s Suggested Retail Price for the machine configuration shown. The MSRP price shown includes the features and attachments (if any) shown as being included at no cost with the machine configuration as well as all reasonable Dealer handling, preparation or similar costs or fees. The MSRP does not include taxes, shipping, surcharges, assembly charges, destination, freight and/or delivery charges. In addition, the MSRP price does not include (i) any attachments not shown as being included at no cost with the machine configuration, or (ii) any protection plans, such as a Customer Value Agreement or Equipment Protection Plan. This is not an offer for sale. The MSRP price displayed is for informational purposes. Please note that the MSRP may vary among authorized Cat dealers as well as by sales channels for the same dealer in each case for the same product. The actual sales price and terms and conditions of sale for all products are to be solely determined by the selling authorized Cat dealer and agreed to with the purchaser at the time of a final sale. The price shown is in U.S. Dollars and is for products sold in the US.
MSRP
Price listed is Manufacturer's Suggested Retail Price, this price does not include shipping and handling, expedite charges, taxes, dealer installation costs or other dealer charges. Dealers set actual prices, including invoicing currency. The MSRP displayed is for the region selected.
Price listed is Manufacturer's Suggested Retail Price, this price does not include shipping and handling, expedite charges, taxes, dealer installation costs or other dealer charges. Dealers set actual prices, including invoicing currency. The MSRP displayed is for the region selected.