The all-new electric power 2600 Series

This inline 6-cylinder, 12.9-litre engine can generate up to 572 kW of dependable engine power to be used for generator set electrical output up to 625 kVa.

SPEAK TO AN EXPERT
2600EP Header
2600EP Header

The future looks bright

The Perkins® 2606A-E13TAG is built to maximise efficiency, even in the harshest conditions worldwide. So, no matter where you need it the 2600 Series for electric power is ready to deliver for both prime and standby applications.

of
Small package. Big performance.

Small package. Big performance.

Smaller and lighter than the 2206 and 2506, the footprint of the 2600 Series for electric power generation makes it easier to install and manage. This 6-cylinder, 12.9-litre engine boosts a 5% weight reduction compared to the 2206 and a 14% weight reduction compared to the 2506.

of
Performs in the most demanding conditions.

Performs in the most demanding conditions.

The 2600 Series for electric power is designed to perform at altitudes of up to 3,500 metres, and in extreme ambient temperatures as high as 60 C (140 F) and as low as minus 40 C (minus 40 F) with aids.

of
Helps minimise fuel & oil consumption

Helps minimise fuel & oil consumption

Electronically operated fuel injectors and carefully matched turbocharging help the 2600 Series lower fuel consumption by up to 6% compared to the 2206. Optimised air, cooling, and lubrication systems help achieve fuel consumption as low as 182 g/kWhr for 50 Hz and 190 g/kWhr for 60 Hz.

Optimised for uncompromising performance

of

This 6-cylinder, 12.9-litre engine boosts a 5% weight reduction compared to the 2206 and a 14% weight reduction compared to the 2506.

of

Smaller and lighter than the 2206 and 2506, the footprint of the 2600 Series' footprint for electric power generation makes it easier to install and manage. This 6-cylinder, 12.9-litre engine boosts a 5% weight reduction compared to the 2206 and a 14% weight reduction compared to the 2506.

Small Package.  Big Performance.
The All-New Electric Power 2600 Series | Power to weight ratio

Perkins 2606 Engine: High-Performance Power Solutions for Electric Power

The newly announced Perkins® 2606 Electric Power engine is the next step in the journey of the all-new Perkins 2600 Series engine platform.

Read more
Perkins 2606 Engine blog post
Perkins 2606 Engine blog post

Need help finding a Distributor near you?

ACCESS THE LOCATOR

Perkins® 2606A-E13TAG

Built on a proven, inline 6-cylinder platform using the latest common rail fuel injection systems, the 12.9L Perkins® 2606A-E13TAG is ready to deliver dependable electric power. For prime applications, that means consistently providing power outputs of 350-500 kVa (50Hz) and 320-455 kWe (60Hz) when and where you need it most.

VIEW FULL SPECS
Perkins® 2606A-E13TAG
Perkins® 2606A-E13TAG
of
Explore the Perkins® 2606A-E13TAG

Designed with durability in mind.

Our engineering team designed the Perkins® 2606AE13TAG on the same foundation as its proven heavy-duty industrial counterpart. This enables this engine to power critical applications worldwide and helps ensure durable performance from the start. Key-designed core components help simplify necessary maintenance. From its single, convenient electronic connection point to oil and fuel service intervals extending up to 1,000 hours, this engine does more to help keep you up and running longer.

Designed with durability in mind.
Designed with durability in mind.

A powerfully wise investment

Every aspect of the 2600 for electric power generation is focused on supplying power that maximises efficiency wherever possible while considering total ownership costs. That means starting with intelligent engine design, monitoring performance through Engine Management System EMS, and delivering the lifetime of support needed to keep applications running smoothly—from standard maintenance routines to quick parts delivery.

Power rating

The 2600 Series delivers a powerful 321-523 kW of prime power and 365-572 kW for standby requirements. It can switch between 50 Hz and 60 Hz frequencies to deliver greater versatility and flexibility to match the needs of your region and application. The 2606A-E13TAG models can be switched to the 2606C-E13TAG models, allowing them to achieve EU Stage II equivalent emissions.

Power rating
Power rating

Load acceptance

The 2600 series for electric power delivers clean, rapid starting, impressive steady-state and transient response. The 2606AE13TAG achieves up to 96% cold prime first step, G2. 80% for 50 Hz and 96% for 60 Hz).

Load acceptance
Load acceptance

Service intervals

Avoid costly downtime with extended oil and fuel filter service change intervals of up to 1,000 hours – even when using unique regional diesel fuels in harsh environments. Hydraulic lash adjusters and electric priming pumps are only some of the core components that make this engine service-friendly.

Service intervals
Service intervals

Fuel system and flexibility

The 2600 is built to withstand traditionally dirty fuels better than legacy 13 and 15L engines (ISO4406:1999). Its next-gen common rail injectors help extend performance life and feature Zero Static Leak technology. The electronic high-pressure unit injectors give low exhaust emissions, good fuel economy and high torque. Multi-shot injection improves combustion and reduces noise (2-3 dB over current 2206).

The 2606 engine is compatible with renewable liquid fuels such as 100% hydrotreated vegetable oils (HVO), B100 distilled Biodiesel, and up to B100 fatty acid methyl ester (FAME) standard biodiesel by working with your Perkins distributor*. Additionally, its core architecture supports the future development of spark-ignited natural-gas and hydrogen fuel capabilities.

Fuel System
Fuel System

Global network, powerful support

The global Perkins distributor network ensures you are never far from the expert support you need to succeed in your operations. From on-hand engine experts to a lineup of ready-to-deploy genuine replacement parts, our worldwide distributors deliver local support no matter where work takes you.

Global network, powerful support
Global network, powerful support

Get the most out of your engine.

To help ensure you’re always getting optimised performance, Perkins offers comprehensive warranty and coverage agreements that cover critical parts and usage milestones— like Perkins® Platinum Protection, which extends your standard coverage beyond the warranty period to as much as ten years of 15,000 hours. Perkins® Hypercare covers parts and services and comprehensive repair and maintenance plans, all to help keep your engine running like new for longer.

Learn more
Get the most out of your engine.
Get the most out of your engine.

Connect with your nearest Perkins Electric Power solutions distributor

For more information about the 2600 Series for Electric Power, fill out the form below, and your local distributor will contact you soon.
 

Address Not Suggested