1408-1876 kVA (1127-1501 kWe)1408-1876 kVA (1127-1501 kWe)
1020-1875 kVA (816-1500 kWe)1020-1875 kVA (816-1500 kWe)
1400-2500 kVA (1120-2000 kWe)1400-2500 kVA (1120-2000 kWe)
Rated Speed
1800 rpm1800 rpm
1500 rpm1500 rpm
1500 rpm1500 rpm
Emission Standards
Emissions
U.S. EPA Stationary Emergency Engine emits equivalent to Tier 2U.S. EPA Stationary Emergency Engine emits equivalent to Tier 2
Fuel OptimisedFuel Optimised
Fuel OptimisedFuel Optimised
50 Hz Typical Electrical Output
Prime
-
1275-1710 kVA (1020-1368 kWe)1275-1710 kVA (1020-1368 kWe)
1750-2250 kVA (1400-1800 kWe)1750-2250 kVA (1400-1800 kWe)
Standby
-
1400-1875 KVA (1120-1500 kWe)1400-1875 KVA (1120-1500 kWe)
1925-2500 kVA (1540-2000 kWe)1925-2500 kVA (1540-2000 kWe)
Baseload
-
1020-1368 kVA (816-1094 kWe)1020-1368 kVA (816-1094 kWe)
-
60 Hz Typical Electrical Output
Prime
1408-1688 kVA (1127-1351 kWe)1408-1688 kVA (1127-1351 kWe)
-
-
Standby
1563-1876 kVA (1250-1501 kWe)1563-1876 kVA (1250-1501 kWe)
-
-
General
Number of Cylinders
12 Vee12 Vee
12 Vee12 Vee
1616
Displacement
2797.3 in³45.84 l
2797.3 in³45.84 l
3728.6 in³61.1 l
Aspiration
Turbocharged and air-to-air chargecooledTurbocharged and air-to-air chargecooled
Turbocharged and air-to-air chargecooledTurbocharged and air-to-air chargecooled
Turbocharged and air-to-water chargecooledTurbocharged and air-to-water chargecooled
Bore
6.3 in160 mm
6.3 in160 mm
6.3 in160 mm
Stroke
7.5 in190 mm
7.5 in190 mm
7.5 in190 mm
Combustion System
Direct injectionDirect injection
Direct injectionDirect injection
Direct injectionDirect injection
Compression Ratio
13.8:113.8:1
13.8:113.8:1
13.8:113.8:1
Aftertreatment
NoneNone
N/AN/A
NoneNone
Total Lubricating Oil Capacity
41.61 gal (US)157.5 l
-
56.3 gal (US)213 l
Total Coolant Capacity
58.38 gal (US)221 l
-
25.1 gal (US)95 l
Rotation from Flywheel End
Anti-clockwiseAnti-clockwise
Anti-clockwiseAnti-clockwise
Anti-clockwiseAnti-clockwise
Cooling System
LiquidLiquid
WatercooledWatercooled
LiquidLiquid
Typical Alternator Efficiency
95%95%
95%95%
95%95%
Switchable
NoNo
NoNo
NoNo
Electro Unit Dimensions
Width
-
-
144.7 in3675 mm
Dry Weight
-
-
81.7 in2076 mm13510 lb6127 kg
Height
-
-
49.6 in1260 mm
Wet Weight
-
-
14147 lb6416 kg
ElectropaK Dimensions
Length
163.1 in4143 mm
154.1 in3913 mm
-
Width
86.6 in2200 mm
86.6 in2200 mm
-
Height
89.5 in2273 mm
102.9 in2614 mm
-
Dry Weight
12919 lb5860 kg
12919 lb5860 kg
-
Wet Weight
13735 lb6230 kg
-
-
Disclaimer
Note 1
*Generator powers are typical and based on typical alternator efficiencies and a power factor (cos θ) or 0.8*Generator powers are typical and based on typical alternator efficiencies and a power factor (cos θ) or 0.8
*Final dimensions dependent on selected options*Final dimensions dependent on selected options
*Final dimensions dependent on selected options*Final dimensions dependent on selected options
Note 2
*Final dimensions dependent on selected options*Final dimensions dependent on selected options
-
-
Definitions
Prime Power
-
Unlimited hours usage with an average load factor of 80 percent of the published prime power over each 24 hour period.
A 10 percent overload is available for one hour in every 12 hours operation.Unlimited hours usage with an average load factor of 80 percent of the published prime power over each 24 hour period.
A 10 percent overload is available for one hour in every 12 hours operation.
Unlimited hours usage with an average load factor of 80 percent of the published prime power over each 24 hour period.
A 10 percent overload is available for one hour in every 12 hours operation.Unlimited hours usage with an average load factor of 80 percent of the published prime power over each 24 hour period.
A 10 percent overload is available for one hour in every 12 hours operation.
Standby Power
-
Limited to 500 hours usage with an average load factor of 80 percent of the published standby power rating over each
24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted.Limited to 500 hours usage with an average load factor of 80 percent of the published standby power rating over each
24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted.
Limited to 500 hours usage with an average load factor of 80 percent of the published standby power rating over each
24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted.Limited to 500 hours usage with an average load factor of 80 percent of the published standby power rating over each
24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted.
Continuous operating power (COP)
-
-
Unlimited hours usage with an average load factor of 100 percent of the published continuous operating power. No overload is permitted on continuous operating power.Unlimited hours usage with an average load factor of 100 percent of the published continuous operating power. No overload is permitted on continuous operating power.
Emergency standby power (ESP)
Limited to 200 hours usage per year with an average load factor of 80 percent of the published ESP rating over each 24 hour period.Limited to 200 hours usage per year with an average load factor of 80 percent of the published ESP rating over each 24 hour period.
-
-
Baseload
-
Unlimited hours usage with an average load factor of 100 percent of the published continuous
operating power. No overload is permitted on continuous operating power.Unlimited hours usage with an average load factor of 100 percent of the published continuous
operating power. No overload is permitted on continuous operating power.
Unlimited hours usage with an average load factor of 100 percent of the published continuous
operating power. No overload is permitted on continuous operating power.Unlimited hours usage with an average load factor of 100 percent of the published continuous
operating power. No overload is permitted on continuous operating power.
Data centre power (DCP)
Power available for variable or continuous electrical loads in a data centre application. Up to 100 percent load factor of the published DCP power is permitted for unlimited time. An overload of 10 percent is permitted for one hour in every 12 hours of operation*. DCP power definition relies on ISO8528-1 2018 standard to be followed by generator set manufacturer, and will support Tier I to Tier IV classifications of data centres as per UPTIME institute guidelines.Power available for variable or continuous electrical loads in a data centre application. Up to 100 percent load factor of the published DCP power is permitted for unlimited time. An overload of 10 percent is permitted for one hour in every 12 hours of operation*. DCP power definition relies on ISO8528-1 2018 standard to be followed by generator set manufacturer, and will support Tier I to Tier IV classifications of data centres as per UPTIME institute guidelines.
-
Power available for variable or continuous electrical loads in a data centre application. Up to 100 percent load factor of the published DCP power is permitted for unlimited time. An overload of 10 percent is permitted for one hour in every 12 hours of operation*. DCP power definition relies on ISO8528-1 2018 standard to be followed by generator set manufacturer, and will support Tier I to Tier IV classifications of data centres as per UPTIME institute guidelines. *No overload permitted for 5016TRG3X rating. For datacentre enquiries, please ensure to contact your local Perkins applications representative.Power available for variable or continuous electrical loads in a data centre application. Up to 100 percent load factor of the published DCP power is permitted for unlimited time. An overload of 10 percent is permitted for one hour in every 12 hours of operation*. DCP power definition relies on ISO8528-1 2018 standard to be followed by generator set manufacturer, and will support Tier I to Tier IV classifications of data centres as per UPTIME institute guidelines. *No overload permitted for 5016TRG3X rating. For datacentre enquiries, please ensure to contact your local Perkins applications representative.
Limited-time running power (LTP)
-
-
Maximum of 500 hours annual usage with an average load factor of 100 percent of the published LTP power.Maximum of 500 hours annual usage with an average load factor of 100 percent of the published LTP power.
Compare models by clicking "Add a Model" above to load specification data.
Please note: You are not currently able to compare with competitors. Please check again at a later date.
Dealer Price
The displayed pricing identified as "Price" is the price that the Dealer sets for the particular machine configuration shown. The Price shown includes the features and attachments (if any) shown as being included at no cost with the machine configuration as well as all reasonable Dealer handling, preparation or similar costs or fees. The Price does not include taxes, shipping, surcharges, assembly charges, destination, freight and/or delivery charges. In addition, the Price does not include (i) any attachments not shown as being included at no cost with the machine configuration, or (ii) any protection plans, such as a Customer Value Agreement or Equipment Protection Plan. This is not an offer for sale. The Price displayed is for informational purposes only. The actual prices and terms and conditions of sale for all products are to be solely determined by the selling authorized Cat dealer and agreed to with the purchaser at the time of a final sale. The price shown is in U.S. Dollars and is for products sold in the US.
Starting at MSRP
This is not an offer for sale. The MSRP price displayed is for informational purposes. Please note that the MSRP may vary by authorized Cat dealer for the same product. The actual price and terms and conditions of sale for all products are to be solely determined by the selling authorized Cat dealer at the time of sale. Taxes, shipping & handling charges, surcharges, assembly charges, destination, freight and/or delivery charges are not included in the MSRP shown and such charges will be material in some locations (including but not limited to Alaska, Hawaii, Guam, and the Pacific Islands). The displayed pricing identified as the “MSRP” price includes features shown for the lowest priced machine configuration on the page accessed through the “Shop Now” button and does not include any attachments or protection plans.
Starting at MSRP
Price listed is Manufacturer's Suggested Retail Price, this price does not include shipping and handling, expedite charges, taxes, dealer installation costs or other dealer charges. Dealers set actual prices, including invoicing currency. The MSRP displayed is for the region selected.
Price listed is Manufacturer's Suggested Retail Price, this price does not include shipping and handling, expedite charges, taxes, dealer installation costs or other dealer charges. Dealers set actual prices, including invoicing currency. The MSRP displayed is for the region selected.