Total Power Range
Gross Mechanical Output | 884-1396 kWm 884-1396 kWm |
Typical Electrical Output | 989-1600 kVA (791-1280 kWe) 989-1600 kVA (791-1280 kWe) |
Rated Speed | 1500/1800 rpm 1500/1800 rpm |
Key Specs
The Perkins 4012 range packs a real performance punch, with 12 cylinders and 46 litre displacement providing all the power you need. The range's diesel ElectropaK engines are supplied complete with radiator and air cleaner, or as engine only. They provide 989-1600 kVA generator output, with exceptional power-to-weight ratios. The compact design of the engines makes them easy to transport and install.
Gross Mechanical Output | 884-1396 kWm 884-1396 kWm |
Typical Electrical Output | 989-1600 kVA (791-1280 kWe) 989-1600 kVA (791-1280 kWe) |
Rated Speed | 1500/1800 rpm 1500/1800 rpm |
Prime | 1253-1500 kVA 1253-1500 kVA |
Standby | 1385-1600 kVA 1385-1600 kVA |
Baseload | 989-1079 kVA 989-1079 kVA |
Prime | 1002-1200 kWe 1002-1200 kWe |
Standby | 1108-1280 kWe 1108-1280 kWe |
Baseload | 791-864 kWe 791-864 kWe |
Emissions | Fuel Optimised Fuel Optimised |
Number of Cylinders | 12 Vee 12 Vee |
Bore | 6.3 in 160 mm |
Stroke | 7.5 in 190 mm |
Displacement | 2797 in³ 45.8 l |
Compression Ratio | 13:1/13.6:1 13:1/13.6:1 |
Aspiration | Turbocharged and air-to-water charge cooled Turbocharged and air-to-water charge cooled |
Combustion System | Direct injection Direct injection |
Rotation from Flywheel End | Anti-clockwise Anti-clockwise |
Cooling System | Liquid Liquid |
Aftertreatment | - - |
Typical Alternator Efficiency | 96% 96% |
Switchable | No No |
Length | 88.8 in 2255 mm |
Width | 146 in 3714 mm |
Height | 70.1 in 1780 mm |
Dry Weight | 9702 lb 4400 kg |
Note 1 | *Final dimensions dependent on selected options *Final dimensions dependent on selected options |
Prime Power | Unlimited hours usage with an average load factor of 80% of the published prime power over each 24 hours period. A 10% overload is available for 1 hour in every 12 hours operation. Unlimited hours usage with an average load factor of 80% of the published prime power over each 24 hours period. A 10% overload is available for 1 hour in every 12 hours operation. |
Standby Power | Limited to 500 hours annual usage with an average load factor of 80% of the published standby power rating over each 24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted on standby power. Limited to 500 hours annual usage with an average load factor of 80% of the published standby power rating over each 24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted on standby power. |
Baseload | Unlimited hours usage with an average load factor of 100% of the published baseload power. No overload is permitted on baseload power. Unlimited hours usage with an average load factor of 100% of the published baseload power. No overload is permitted on baseload power. |