4006D-E23TAG Electric Power Diesel Engine

Certified Models 4006D-E23TAG

Speak to an expert Find your Distributor

Key Specs

Gross Mechanical Output
668-732 kWm
668-732 kWm
Typical Electrical Output
750-825 kVA (600-660 kWe)
750-825 kVA (600-660 kWe)
Emissions
India CPCB ll
India CPCB ll

Overview

Perkins are pleased to introduce its first electronic engine to the Perkins® 4000 Series family. The 4006 electronic engine is designed specifically to produce lower emissions and provide competitive performance at the same time. This Tier 3 emissions capable engine meets the electric power industry’s growing demand for greener power along with superior performance and reliability.

The 4006D-E23TAG2 is a turbocharged and air-to-air charge cooled, 6 cylinder diesel engine with full electronic control enabling lower emissions, easy diagnostic capability. This engine also offers world leading load acceptance and ambient de-rate capability. Along with exceptional power to weight ratio, this engine also benefits from low cost of ownership and long service intervals; all characteristics essential to the power generation market.

Product Specifications for 4006D-E23TAG

Gross Mechanical Output 668-732 kWm 668-732 kWm
Typical Electrical Output 750-825 kVA (600-660 kWe) 750-825 kVA (600-660 kWe)
Rated Speed 1500 rpm 1500 rpm
Prime 750 kVA 750 kVA
Standby 825 kVA 825 kVA
Emissions India CPCB ll India CPCB ll
Number of Cylinders 6 inline 6 inline
Bore 6.3 in 160 mm
Stroke 7.5 in 190 mm
Displacement 1399 in³ 23 l
Compression Ratio 12.8:1 12.8:1
Aspiration Turbocharged and air-to-air charge cooled Turbocharged and air-to-air charge cooled
Combustion System Direct injection Direct injection
Rotation from Flywheel End Anti-clockwise Anti-clockwise
Cooling System Liquid Liquid
Aftertreatment - -
Typical Alternator Efficiency 94% 94%
Switchable No No
Length 107.5 in 2730 mm
Width 66.5 in 1690 mm
Height 83.7 in 2126 mm
Dry Weight 6361 lb 2885 kg
Note 1 *Final dimensions dependent on selected options *Final dimensions dependent on selected options
Prime Power Unlimited hours usage with an average load factor of 80% of the published prime power over each 24 hour period. A 10% overload is available for 1 hour in every 12 hours operation. Unlimited hours usage with an average load factor of 80% of the published prime power over each 24 hour period. A 10% overload is available for 1 hour in every 12 hours operation.
Standby Power Limited to 500 hours annual usage with an average load factor of 80% of the published standby power rating over each 24 hour period. Up to Limited to 500 hours annual usage with an average load factor of 80% of the published standby power rating over each 24 hour period. Up to
Baseload Unlimited hours usage with an average load factor of 100% of the published baseload power. No overload is permitted on baseload power. Unlimited hours usage with an average load factor of 100% of the published baseload power. No overload is permitted on baseload power.

4006D-E23TAG Standard Equipment

Air inlet system

  • Mounted air filter and turbocharger

Cooling system

  • Radiator supplied loose incorporating air-to-air charge cooler
  • System designed for ambients up to 50ºC (122ºF)
  • Twin thermostats, water pump

Electrical equipment

  • 24V starter motor, 24V alternator with integral voltage regulator and DC output
  • High coolant temperature protection switch
  • Low oil pressure monitored through ECM

Flywheel and housing

  • SAE ‘0' flywheel housing
  • SAE J620 size 18 flywheel

Fuel system

  • Digital governing to ISO 8528-5 Class G2 with isochronous capability
  • Mechanically actuated electronically controlled unit fuel injectors with full authority electronic control
  • Full flow spin-on filters

Lubrication system

  • Full flow spin-on oil filters
  • Wet sump with filler and dipstick

Optional equipment

  • Exhaust counter flanges
  • Immersion heater
  • Secondary electric start
  • Single exhaust outlet pipe

See how 4006D-E23TAG compares against frequently compared products.