Total Power Range
Gross Mechanical Output | 501-555 kWm 501-555 kWm |
Typical Electrical Output | 569-625 kVA (455-500 kWe) 569-625 kVA (455-500 kWe) |
Rated Speed | 1800 rpm 1800 rpm |
Part of our 2000 Series, the 6 cylinder Perkins 2800 range diesel engine is ideal for your power generation requirements from 591-750 kVA, whether prime or standby power. Building on its already strong EPA Tier 4 electric power range, Perkins is pleased to announce the addition of the Tier 4 Final certified 2806 ElectropaK. The 2806F-E18TAG1 is a turbocharged and air-to-air charge cooled 6 cylinder diesel engine of 18.1 litres displacement. Its premium features provide economic and durable operation, low gaseous emissions, and advanced overall performance and reliability.
Gross Mechanical Output | 501-555 kWm 501-555 kWm |
Typical Electrical Output | 569-625 kVA (455-500 kWe) 569-625 kVA (455-500 kWe) |
Rated Speed | 1800 rpm 1800 rpm |
Prime | 455 kWe 455 kWe |
Standby | 500 kWe 500 kWe |
Emissions | U.S. EPA Tier 4 U.S. EPA Tier 4 |
Number of Cylinders | 6 vertical inline 6 vertical inline |
Bore | 5.7 in 145 mm |
Stroke | 7.2 in 183 mm |
Displacement | 1106 in³ 18.1 l |
Compression Ratio | 16.0:1 16.0:1 |
Aspiration | Turbocharged and air-to-air charge cooled Turbocharged and air-to-air charge cooled |
Combustion System | Electronic unit injection Electronic unit injection |
Rotation from Flywheel End | Anti-clockwise Anti-clockwise |
Cooling System | Liquid Liquid |
Aftertreatment | DOC+DPF+SCR DOC+DPF+SCR |
Typical Alternator Efficiency | 95% 95% |
Switchable | No No |
Length | 97 in 2466 mm |
Width | 59.3 in 1506 mm |
Height | 70 in 1773 mm |
Dry Weight | 4552 lb 2065 kg |
Length | 97 in 2457 mm |
Width | 60 in 1520 mm |
Height | 78 in 1985 mm |
Dry Weight | 4552 lb 2065 kg |
Length | 43.5 in 1106 mm |
Width | 45.8 in 1164 mm |
Height | 27.4 in 695 mm |
Weight | 580 lb 263 kg |
Note 1 | *Final dimensions dependent on selected options *Final dimensions dependent on selected options |
Prime Power | Variable load. Unlimited hours usage with an average load of 70% of the published prime power rating. A 10% overload is available for 1 hour in every 12 hour of operation. Variable load. Unlimited hours usage with an average load of 70% of the published prime power rating. A 10% overload is available for 1 hour in every 12 hour of operation. |
Standby Power | Variable load. Limited to 500 hours annual usage up to 300 hours of which may be continuous running. No overload is permitted. Variable load. Limited to 500 hours annual usage up to 300 hours of which may be continuous running. No overload is permitted. |