Total Power Range
Gross Mechanical Output | 6.0-6.6 kWm 6.0-6.6 kWm |
Typical Electrical Output | 5.8-6.4 kVA (4.7-5.1 kWe) 5.8-6.4 kVA (4.7-5.1 kWe) |
Rated Speed | 1500 rpm 1500 rpm |
The Perkins® 400 Series engine family continues to set new standards in the compact engine market. Developed alongside customers to fulfil their needs in the generator set market, they have been designed to comply with stringent emissions regulations for EU and USA. The 403 Product range offers a highly compact Perkins electro units and electropaKs to provide robust 3 cylinder diesel engines designed to provide economic and durable operation for prime power applications, hitting the key power nodes required by the power generation industry.
The 400 Series mechanical engine range offers optimised fuel consumption and low oil consumption whilst meeting the Stage V and Tier 4 Final emissions standards; all delivered from a reliable mechanical engine to minimise cost of ownership.
Gross Mechanical Output | 6.0-6.6 kWm 6.0-6.6 kWm |
Typical Electrical Output | 5.8-6.4 kVA (4.7-5.1 kWe) 5.8-6.4 kVA (4.7-5.1 kWe) |
Rated Speed | 1500 rpm 1500 rpm |
Prime | 5.6 kVA 5.6 kVA |
Standby | 6.1 kVA 6.1 kVA |
Emissions | EU Stage V EU Stage V |
Number of Cylinders | 3 inline 3 inline |
Bore | 2.6 in 67 mm |
Stroke | 2.8 in 72 mm |
Displacement | 46.5 in³ 0.7 l |
Compression Ratio | 23.5:1 23.5:1 |
Aspiration | Naturally aspirated Naturally aspirated |
Combustion System | Mechanical indirect injection Mechanical indirect injection |
Rotation from Flywheel End | Anti-clockwise Anti-clockwise |
Cooling System | Watercooled Watercooled |
Aftertreatment | - - |
Typical Alternator Efficiency | 83.20% 83.20% |
Switchable | No No |
Length | 25.4 in 645 mm |
Width | 17.4 in 442 mm |
Height | 24.8 in 630 mm |
Dry Weight | 192 lb 87 kg |
Note 1 | *Final dimensions dependent on selected options *Final dimensions dependent on selected options |
Prime Power | Unlimited hours usage with an average load factor of 80% of the published prime power over each 24 hour period. A 10% overload is available for 1 hour in every 12 hours operation. Unlimited hours usage with an average load factor of 80% of the published prime power over each 24 hour period. A 10% overload is available for 1 hour in every 12 hours operation. |
Standby Power | Limited to 500 hours annual usage with an average load factor of 80% of the published standby power rating over each 24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted on standby power. Limited to 500 hours annual usage with an average load factor of 80% of the published standby power rating over each 24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted on standby power. |