Total Power Range
Gross Mechanical Output | 317-421 kWm 317-421 kWm |
Typical Electrical Output | 360-469 kVA (288-375 kWe) 360-469 kVA (288-375 kWe) |
Rated Speed | 1800 rpm 1800 rpm |
Part of our 2000 Series, the 6 cylinder Perkins 2200 range diesel engine is ideal for your power generation requirements from 350-500 kVA, whether prime or standby power. Building on its already strong EPA Tier 4 electric power range, Perkins is pleased to announce the addition of the Tier 4 Final certified 2206 ElectropaK. The 2206F-E13TAG3 is a turbocharged and air-to-air charge cooled 6 cylinder diesel engine of 12.5 litres displacement. Its premium features provide economic and durable operation, low gaseous emissions, and advanced overall performance and reliability.
Gross Mechanical Output | 317-421 kWm 317-421 kWm |
Typical Electrical Output | 360-469 kVA (288-375 kWe) 360-469 kVA (288-375 kWe) |
Rated Speed | 1800 rpm 1800 rpm |
Prime | 360 KVA 360 KVA |
Standby | 400 kVA 400 kVA |
Prime | 340 kWe 340 kWe |
Standby | 375 kWe 375 kWe |
Emissions | U.S. EPA Tier 4 U.S. EPA Tier 4 |
Number of Cylinders | 6 vertical inline 6 vertical inline |
Bore | 5.12 in 130 mm |
Stroke | 6.1 in 157 mm |
Displacement | 762.8 in³ 12.5 l |
Compression Ratio | 17.0:1 17.0:1 |
Aspiration | Turbocharged and air-to-air charge cooled Turbocharged and air-to-air charge cooled |
Combustion System | Electronic unit injection Electronic unit injection |
Rotation from Flywheel End | Anti-clockwise Anti-clockwise |
Cooling System | Liquid Liquid |
Aftertreatment | DOC+DPF+SCR DOC+DPF+SCR |
Typical Alternator Efficiency | 95% 95% |
Switchable | Yes Yes |
Length | 93.1 in 2365 mm |
Width | 49.2 in 1250 mm |
Height | 70.7 in 1795 mm |
Dry Weight | 3197 lb 1450 kg |
Length | 42 in 1066 mm |
Width | 42.4 in 1077 mm |
Height | 23 in 591 mm |
Weight | 564 lb 256 kg |
Note 1 | *Final dimensions dependent on selected options *Final dimensions dependent on selected options |
Prime Power | Variable load. Unlimited hours usage with an average load of 70% of the published prime power rating. A 10% overload is available for 1 hour in every 12 hour of operation. Variable load. Unlimited hours usage with an average load of 70% of the published prime power rating. A 10% overload is available for 1 hour in every 12 hour of operation. |
Standby Power | Variable load. Limited to 500 hours annual usage up to 300 hours of which may be continuous running. No overload is permitted. Variable load. Limited to 500 hours annual usage up to 300 hours of which may be continuous running. No overload is permitted. |